Clearview® HIV 1/2 STAT-PAK is a rapid
qualitative screening test for the detection of antibodies to HIV-1
and HIV-2 in human whole blood, serum and plasma.
CLIA Waived, simple two-step procedure for whole
blood.
Clearly different
Clearview's innovative technology provides highly accurate
detection of HIV-1 and HIV-2.
- Fast: two easy steps with a reactive
result in as little as 15 minutes
- Easy: CLIA-waived, easy-to-use test
requires no training
- Reliable: built-in control ensures
accuracy
- Flexible: use with multiple specimen
types - whole blood (fingerstick or venipuncture), serum or
plasma
Clearly better
Clearview® HIV 1/2 STAT-PAK provides answers for
immediate and necessary treatment.
- Supports early screening and diagnosis of human
immunodeficiency virus
- Detection and proper treatment may prevent transmission to an
unborn child, as well as to sexual partners
- Early diagnosis and treatment can lead to a prolonged survival
rate
- 24 month shelf life provides flexibility to the
laboratory
- Reliable results - 99.7% sensitive, 99.9% specific
About HIV
Human immunodeficiency virus (HIV) infection and acquired
immunodeficiency syndrome (AIDS) remain leading causes of illness
and death in the United States. However, at the end of 2003, of the
approximately 1.0--1.2 million persons estimated to be living with
HIV in the United States, an estimated one quarter
(252,000--312,000 persons) were unaware of their infection and
therefore unable to benefit from clinical care to reduce morbidity
and mortality. A number of these persons are likely to have
transmitted HIV unknowingly. 1
Treatment has improved survival rates dramatically, especially
since the introduction of highly active antiretroviral therapy
(HAART) in 1995. However, progress in effecting earlier diagnosis
has been insufficient. The good news is that the new CDC guidelines
have removed much of the barriers to screening and now encourages
testing all persons 13-64 years of age in the United States.
New HIV Screening Guidelines
In September 2006, the CDC announced revised recommendations for
HIV testing of adults, adolescents, and pregnant women in
health-care settings. The new guidelines highlight:
- Screening for all patients aged 13-64 years regardless of
risk
- Patients are notified that testing will be performed unless
they decline (opt-out screening)
- Testing process is streamlined to lower the barriers of
pre-test counseling and documented written consent
- High risk populations such as IV drug users and their sex
partners and men who have sex with men should be tested
annually
This represents a substantial change from earlier
recommendations:
- Offer HIV testing routinely to all patients only in health-care
settings with high HIV prevalence
- Conduct targeted screening on the basis of risk behaviors for
patients in low-prevalence settings
- Require informed, written consent prior to testing
- Pre-test counseling
Product
Overview
The Clearview® HIV 1/2 STAT-PAK is a rapid in vitro
qualitative immunoassay for the detection of antibodies to HIV1 and
HIV 2 in human whole blood, serum and plasma.
With its simple, two-step procedure, Clearview HIV 1/2 STAT-PAK
is quick and easy to use, delivering clear, dependable results in
just 15 minutes. Plus, Clearview HIV 1/2 STAT-PAK is waived for
whole blood and requires a very small sample amount, making it
easier to run and manage in a busy laboratory environment.
Clearview HIV-1/2 STAT-PAK will help healthcare workers diagnose
individual infection, prevent mother-to-child transmission, and
monitor HIV prevalence.
FAQ’s
1. How sensitive is Clearview HIV 1/2
STAT-PAK?
99.7% sensitive and 99.9% specific for all sample types
2. How should Clearview HIV 1/2 STAT-PAK be
stored?
Store at 8° to 30°C (46° to 86°F)
3. What type of patient sample do I have to
use?
Human serum, plasma and whole blood from venipuncture or
fingerstick. For Serum or Plasma, collect specimen in a tube not
containing any anticoagulant (serum), and in a tube containing
citrate, heparin, or EDTA (plasma). For whole blood either through
venipuncture or fingerstick (fill the sample loop provided in the
kit).
4. How critical is the timing?
The timing is critical and you cannot obtain the correct results if
you do not follow the instructions exactly.
5. How long are the results stable?
The result can be read from 15 to 20 minutes.
6. The Test Line was fainter than the Control Line, what
does this mean?
The test result is reactive even if the Test Line appears lighter
or darker than the Control Line.
7. No line has appeared in the Control Window, what does
this mean?
The test is invalid. You will have to use a new device and run the
test again.
8. What is the shelf-life of Clearview HIV 1/2
STAT-PAK?
Up to a maximum of 24 months from the date of manufacture
9. If I add whole blood and forget to add running buffer
will the test still run?
You cannot obtain the correct result. It should be tested
again.
10. Would a negative result conclude that a patient does
not have HIV?
A non-reactive result with Clearview HIV 1/2 STAT-PAK does not
exclude the possibility of infection with HIV. A false negative
result can occur in the following circumstances;
- low levels of antibody (e.g., early seroconversion specimens)
are below the detection limit of the test
- infection with a variant of the virus that is less detectable
by the Clearview assay configuration
- HIV antibodies in the patient that do not react with specific
antigens utilized in the assay configuration - in exceptional cases
this may lead to observation of false negative results
- specimens handling conditions which result in loss of HIV
antibody multivalency.
11. What are the storage conditions for Serum and Plasma
samples?
Serum and plasma samples can be run immediately or refrigerate them
at 2 to 8°C (36 to 46°F) following collection. These specimens
should be tested within 3 days of collection. If specimens are not
tested within 3 days of collection, serum or plasma specimens
should be frozen at -20°C (-4°F) or colder.
12. What are the storage conditions for whole blood
samples?
Venous whole blood can be run immediately or
refrigerated at 2 to 8°C (36 to 46°F) following collection. Venous
whole blood may be stored for up to 3 days between 2 and 8°C (36 to
46°F) before testing. DO NOT FREEZE WHOLE BLOOD!
Whole blood collected by fingerstick should be tested
immediately.
13. What volume does the sample loop
deliver?
5ul
Reference
1. www.cdc.gov
Legal
Manufactured by Chembio Diagnostic Systems, Inc., Medford, NY for
Inverness Medical Professional Diagnostics under issued patents
U.S. 6,352,862; 6,534,320; 5,622,871; 5,656,503;
6,187,598; 4,956,302; 6,627,459; 5,602,040; 6,228,660; 6,818,455;
5,120,643; 5,714,389; 5,989,921; 6,485982; and additional patents
pending that are owned or licensed by a member of the Inverness
Medical family of companies. Corresponding rights granted or
pending elsewhere.